Hello, I recently acquired a MAN TGL 8,210 from 2006, which has replaced the previous owner with any reasons for an overvoltage damage by trying to give external start-up assistance and thus the truck was temporarily supplied with 48 volts The engine control unit, ZBR, FFR and ECAS ECUs have been replaced, ZBR and FFR only have to be married by the MAN workshop… Now to the actual problem, I have in the central distribution in the dashboard, passenger Side in the fuse box still a few short circuits in the following cables or electric circuits: – 30 000 after 77 008 – 30 011 after 30 010 relays K1127 93 319 16 080 39 104 fuse 18 and 21 I hope someone can help me with the assignment of the cables!?